Library
Datasheets
As part of VibroSystM’s continuing process of product development and improvement, together with responsible product life-cycle management, certain products may be discontinued and gradually reach obsolescence, and no longer be available and/or supported. For advice on functional replacements and upgrades, or additional information, please contact us.
ZOOM System
AGMS - Air gap monitoring system for hydroelectric generators
EWMS - End winding monitoring system for turboelectric generators
ZOOM System for Hydroelectric Generators
ZOOM System for Turbo-electric Generators
Measuring Chain
Sensor
VSM797S Piezoelectric Accelerometer (500 mV/g)
DCS-400 sensor (0.5-2.5 mm)
FOA-100E Fiber Optic Accelerometer (10 m/Class A 105°C)
FOA-100E Fiber Optic Accelerometer (10 m/Class F 155°C)
FOA-100E Fiber Optic Accelerometer (20 m/Class F 155°C)
FOA-200 Dual-Axis Fiber Optic Accelerometer (10 m/Class A 105°C)
FOA-200 Dual-Axis Fiber Optic Accelerometer (10 m/Class F 155°C)
FOT-200 Fiber optic Temperature sensor (10 m)
MFP-100 Magnetic field probe
MFP-100 Magnetic Flux Sensor for Turbo-Generators
PCS-200 Capacitive proximeter (6 m integral cable/BOA/SMA/0.3-4.3/6.3 mm)
PCS-202 Capacitive Proximity Probe (6 m integral cable/BOA/SMA/0.3-2.3 mm)
PCS-302 Capacitive Proximity Probe with built-in signal conditioner (0.3-2.3 mm)
PCS-304 Capacitive Proximity Probe with built-in signal conditioner (0.5-4.5 mm)
PES-103 Eddy Current Proximity Sensor (0-3 mm)
PES-106 Eddy Current Proximity Sensor (0-6 mm)
PES-110 Eddy Current Proximity Sensor (0-10 mm)
PES-302 Sealed Eddy Current Proximity Sensor (0-2 mm)
PES-305 Sealed Eddy Current Proximity Sensor (0-5 mm)
SBV-202P Capacitive sensor (6 m integral cable/0.3-2.3 mm)
SPES-108 Underwater Eddy Current Proximity Sensor (0-8 mm)
SPES-117 Underwater Eddy Current Proximity Sensor (0-17 mm)
Synchronization Probe
TWR-200 ThermaWatch Rotor
TWS-200 Temperature Sensor
VM3 AIRFLOW air gap sensor (2-20 mm)
VM5 AIRFLOW air gap sensor (2-42 mm)
VM 3.2 air gap sensor (1-10 mm)
VM 6.1 air gap sensor - 0.5 m/1.6 ft Integral cable - (3-30 mm)
Cable-from sensor to conditioner
Cable / Triaxial - SMA/SMA / (10 m/32.8 ft)
Cable / Triaxial - SMA/SMA / (10 m/32.8 ft)
Cable / Triaxial – SMA/SMA / (15 m/49.2 ft)
Cable / Triaxial – SMA/SMA / (10 m/32.8 ft)
Cable / Triaxial – SMA/SMA / (10 m/32.8 ft)
TWR-200 ThermaWatch Rotor 30m extension cable
Cable / Twinax – MFP-100 – AWG 20 / (10 m/32.8 ft)
Cable / Twinax – MFP-100 – AWG 20 / (20 m/65.6 ft)
Conditioner
LIN-33AF-10S conditioner (1-20 mm)
LIN-33AF-15H conditioner (2-20 mm)
LIN-35AF-10S conditioner (2-42 mm)
TWR-200 ThermaWatch Rotor signal conditioner (50Hz)
TWR-200 ThermaWatch Rotor signal conditioner (60Hz)
LIN-332-10S conditioner (1-10 mm)
LIN-361-7I conditioner (3-30 mm)
LIN-361-7I conditioner (5-50 mm)
LIN-302S-6I conditioner (0.3-2.3 mm) (SMA)
LIN-304S-6I conditioner (0.3-4.3 mm)
LIN-306S-6I conditioner (0.3-6.3 mm)
LIN-302VP-6I conditioner (0.3-2.3 mm)
LIN-340-10 conditioner (0.5-2.5 mm)
MFC-100 Magnetic field signal conditioner
Protection box 14-12-8 for 2 LIN-300
Protection box 14-12-8 for 2 LIN-300 with power supply
Protection box 14-12-8 for 2 LIN-300 with terminal blocks
Server & Software
ZOOM & License
ZOOM SOFTWARE SUITE Version 7.4
Acquisition & Protection
ZPU/SFA/CABINET
Standard monitoring cabinet for energy industries
“2-Ch.” Voltage Input Module (0 to 10 V)
“2-Ch.” Voltage Input Module (0 to 5 V)
“2-Ch.” Voltage Input Module (± 10 V)
“2-Ch.” Vibration/Acceleration Input Module (ICP/100 mV/g) (1.13 g)
“2-Ch.” Vibration/Acceleration Input Module (ICP/100 mV/g) (5.65 g)
“2-Ch.” Vibration / Proximity Input Module (-2 to -18 V)
“2-Ch.” Current Input Module (4 to 20 mA)
“2-Ch.” Voltage Input Module (± 5 V)
“2-Ch.” Vibration / Acceleration Input Module (ICP/500 mV/g)
“2-Ch.” Air Gap Input Module
Communication module
Control Module
“2-Ch.” Vibration / Acceleration Input Module (FOA)
“2-Ch.” Vibration / Combo Proximity & Acceleration Input Module
“2-Ch.” Vibration / Velocity Input Module (ICP / 3.94 mV/mm/s)
ZPU-5000 Multi-channel processing instrumentation & monitoring/protection unit
SFA-200 Stray Flux Analyzer Unit
Installation
Cable & Connector
Cable / 4 conductors shielded ’’Zero-Halogen’’ - AWG 22 (m)
Cable / 4 conductors shielded ’’Zero-Halogen’’ - AWG 22 (300 m spool)
Cable / M12 straight connector - 4 wires (100 m/ 328 ft)
M12 Mating straight connector (fem. type, unshielded)
M12 Mating angled connector (fem. type, unshielded)
M12 Mating straight connector (fem. type, shielded)
M12 Mating angled connector (fem. type, shielded)
Flange
Connectorized internal flange (M12 x 9)
Connectorized internal flange (M12 x 12)
Penetration Flange (welded) with safety cover
Services
Field services
ZOOM System Remote Maintenance plan
Technical Support Services
ZOOM System Maintenance Service Contract
Tests & Diagnostics services
Factory services
Special services
VibroSystM Safety Solution for Hazardous Locations
Manuals
797L Piezoelectric Accelerometer Transducer – Installation Manual
VSM797S Piezoelectric Accelerometer – Installation Manual
797V Piezoelectric Velocity Sensor – Installation Manual
DCS-400 Measuring Chains with LIN-340 Signal Conditioner
DM-100 Creep Detection System – Installation Manual
DMV-100 Creep Detection System – Installation Manual
Penetration Flange with Connectorized Internal Flanges ‐ User’s Manual
FOA-Series Fiber Optic Accelerometers User’s Manual
MFM-100 Magnetic Flux Measuring System – Installation Manual
MFP-100 for Turbo Generator User’s Manual
PCS-202SB Measuring Chains with LIN-300 Series Module – Front End Installation
PCS-200ESB Measuring Chains with LIN-300 Series Module – Front End Installation
Front End Installation of the PCS-302 and PCS-304 Measuring Chains
PES-103 Eddy Current Proximity Sensor User’s Manual
PES-106 Eddy Current Proximity Sensor User’s Manual
PES-110 Eddy Current Proximity Sensor User’s Manual
PES-302 User’s Manual
PES-305 User’s Manual
SBV-202P Stator Bar Vibration Measuring Chain User’s Manual
SBV-202 with LIN-302V – Installation Manual
Setting the ZPU-5000 unit in standalone mode Procedure (with ZAC Plugin)
ZOOM Configuration for ZPU-5000 Standalone (c/w: Modbus) User’s Manual
SPES-108 Measuring Chains – User’s Manual
SPES-117 Submersible Proximity Probe – User’s Manual
The State-200 Extension – Installation and Operation Manual
Synchronization Probe User Manual
VM3.12 Capacitive Air Gap Measuring Chains User’s Manual
VM3.2 Capacitive Air Gap Measuring Chains User’s Manual
VM5.1 Capacitive Air Gap Measuring Chains User’s Manual
VM6.1 Capacitive Air Gap Measuring Chains User’s Manual
Linear Displacement Transducer – Installation Manual
XPSP-224 External Power Supply Panel for Measuring Chains User’s Manual
ZOOM Software Suite Version 7.3 – Installation Guide
ZOOM Software Suite Version 7.4 – Installation Guide
ZPU-5000 Acquisition Unit User’s Manual for ZOOM Version 7.2
ZPU-5000 Acquisition Unit User’s Manual for ZOOM Version 7.3
ZPU-5000 Acquisition Unit User’s Manual for ZOOM Version 7.4
Brochures
Complete Monitoring Solutions & Diagnostics services for the Hydro Industry
Complete Monitoring Solutions & Diagnostics services for the Turbo Industry
Application Notes
Mechanical Tolerance Guidelines for Hydroelectric Generators
ZOOM Software Measurement and Graph Types
Air Gap Results Introduction – Pole vs. Time-reference Method
Techniques to Verify Rotor Stability Using Air Gap Measurements
Overview of Typical Factors Affecting the Air Gap of a Hydrogenerator
Understanding ZOOM Shaft Orbit Graph
Stator Sagging on Bulb Generators
Evaluating Relative Thermal Expansion of Stator Using Air Gap Measurements
Technique for Detecting Rotor Rim Vibration
Papers
Avoiding major damage on a new hydrogenerator by monitoring air gap at Igarapava H.E.P.P.
End-winding vibration in large rotating machines
Air gap monitoring system key element to correctly diagnose generator problems
On-line monitoring systems as used by Electronorte at the Tucurui II & Coaracy Nunes power plants
On-line vibration and temperature direct measurement on high voltage devices using fiber optic sensor technology
Air gap monitoring key element to correctly identify source of shaft vibration
Air gap monitoring key element to avoid unnecessary and costly repairs
Tidal power plant bulb unit management through air gap monitoring
Rotor shape vs. rotor field pole shorted turns
On-line condition monitoring solutions for Jirau & Santo Antônio hydroelectric projects
A novel approach to partial discharge monitoring
End-winding vibration monitoring: pivotal in preventing major damage on a large turbo-generator
Concrete Expansion – R.H. Saunders GS Innovative Structural Rehabilitation & Mitigation Effectiveness